AOZ8S204BLS-05

AOZ8S204BLS-05
Attribute
Description
Manufacturer Part Number
AOZ8S204BLS-05
Description
TVS DIODE 5VWM 5.8VC 2WLCSP
Note : GST will not be applied to orders shipping outside of India

Stock:
15000

Distributor: 117

Lead Time: Not specified

Quantity Unit Price Ext. Price
15000 ₹ 3.95 ₹ 59,250.00

Product Attributes

Type Description
Category
Import Duty Classification -
Product Series Line -
IC Encapsulation Type Bulk
Availability Status Active
Device Type Classification Zener
One-Way Signal Paths -
Two-Way Signal Paths 1
Typical Standoff Voltage 5V (Max)
Minimum Breakdown Volts 6V
Max Clamp at Peak Current 5.8V (Typ)
Peak Pulse 10/1000us 8.5A (8/20µs)
Pulse Peak Power 50W
AC Line Surge Guard No
Intended Uses USB
Capacitance at Specific Hz 0.15pF @ 1MHz
Ambient Temp Range -40°C ~ 125°C (TJ)
Quality Grade Level -
Certification Qualification -
Attachment Mounting Style Surface Mount
Component Housing Style 0201 (0603 Metric)
Vendor Package Type 2-WLCSP (0.6x0.3)

Description

Ideally suited for scenarios involving USB. Facilitates 1 bidirectional channels for two-way operation. Provides capacitance at a designated frequency of 0.15pF @ 1MHz. Survives peak pulse current of 8.5A (8/20µs) under 10/1000µs conditions. Maximum signal delay 5.8V (Typ) at voltage for timing-sensitive applications. Mounting style Surface Mount for structural integrity. Operating temperature -40°C ~ 125°C (TJ) for thermal stability. Enclosure Bulk for component protection or transport. Enclosure/case 0201 (0603 Metric) providing mechanical and thermal shielding. Enclosure type 2-WLCSP (0.6x0.3) ensuring device integrity. Maximum pulse power 50W for safeguarding devices. Protection for power lines No against surges and faults. Product condition Active for availability and lifecycle. Manufacturer package type 2-WLCSP (0.6x0.3) for component choice. Category Zener for classification or specification. Minimum breakdown voltage level 6V for safety measures. Maximum clamping voltage at peak current Ipp 5.8V (Typ) for surge protection. Standard reverse standoff voltage 5V (Max) for safeguarding.